010-151 Real Exam Dumps Questions and answers 41-50
Get Full Version of the Exam
http://www.EnsurePass.com/010-151.html
Question No.41
Which tool does a network administrator not need when installing hardware?
-
cable tester
-
wrench set
-
cable wraps
-
needle-nose pliers
-
PCMCIA memory
-
soldering iron with grounded tip
Correct Answer: F
Question No.42
When the Cisco UCS Manager is used to verify the B- or C-Series device, which two types of Overall Status are acceptable and do not indicate a failure? (Choose two.)
-
Online
-
OK
-
Unassociated
-
Active
Correct Answer: BC
Question No.43
What is the correct path to verify the Overall Status of Chassis 1 | Server 3?
-
Equipment Tab gt; Chassis gt; Chassis 1 gt; Servers gt; Server 3 Status tab
-
Equipment Tab gt; Chassis gt; Chassis 1 gt; Servers gt; Server 3 General tab
-
Equipment Tab gt; Chassis gt; Chassis 1 gt; Servers gt; Server 3 FSM tab
-
Servers Tab gt; Chassis gt; Server 3 General tab
-
Status Tab gt; Chassis gt; Chassis 1 gt; Servers gt; Server 3
-
Admin Tab gt; Chassis gt; Chassis 1 gt; Servers gt; Server 3 General tab
Correct Answer: B
Question No.44
If the Overall Status for a Cisco UCS B-Series Blade Server indicates a failure in the Cisco UCS Manager, such as discovery-failed, which statement is true?
-
The server shuts down.
-
The server automatically reboots reboot in 3 minutes.
-
The endpoints on that server cannot be upgraded.
-
The server is online, but the administrator cannot assign a service profile to that blade.
Correct Answer: C
Question No.45
Which action should the administrator take before physically removing a blade server for maintenance or replacement?
-
Force the server to shut down.
-
Disassociate the service profile.
-
Decommission the server.
-
Perform a graceful shutdown of the server.
Correct Answer: C
Question No.46
Which three statements about powering down a Cisco UCS C-Series Rack-Mount Server to perform maintenance or replacement are true? (Choose three.)
-
Standby power mode: Power is supplied only to the service processor and the cooling fans, and it is safe to power off the server from this mode.
-
Power status LED. Green indicates that the server is in main power mode and can be safely powered off.
-
Graceful shutdown: Press and release the power button. The operating system performs a graceful shutdown, and the server goes to standby mode, which is indicated by an amber power status LED.
-
Disconnect the power cords from the power supplies in your server to completely power off the server.
-
Only an emergency shutdown can be performed using the power button on the server front panel.
-
The Cisco UCS C-Series Rack-Mount Server has only one power mode.
Correct Answer: ACD
Question No.47
Which three components are hot swappable in a Cisco UCS Blade Server and Chassis? (Choose three.)
-
Fabric Extender
-
Power supply
-
Heat sink
-
SAS Hard Drive
-
2x8GB Kit DIMMs
-
Mezzanine card
Correct Answer: ABD
Question No.48
Which five things should the administrator verify after performing maintenance or replacing a blade server? (Choose five.)
-
blade server status
-
hard drive status
-
host OS boot status
-
CPU status
-
mezzanine card status
-
memory DIMM status
-
fan and power status
Correct Answer: ABDEF
Question No.49
Which two statements about DIMM replacement in Cisco UCS Servers are true? (Choose two.)
-
In blade servers, DIMMs can be installed in either 1, 2, 4, or 8 DIMMs per channel.
-
Rack-mount and blade servers have memory fault LEDs that indicate which DIMM requires attention.
-
In servers that require pairs of DIMMs, the pairs must be identical (manufacturer, size, part #, and so on).
-
If the memory in a server is not fully populated, you can install DIMMs in any open slot.
Correct Answer: AC
Question No.50
Which three tools are necessary to console into a Cisco UCS C-Series Rack-Mount Server? (Choose three.)
-
Cisco DB-9-to-RJ-45 console cable
-
laptop
-
monitor
-
keyboard
-
KVM dongle
-
USB serial adapter
Correct Answer: CDE
Get Full Version of 010-151 Dumps